CompTIA A+ Core 2 Question H-34

A service technician is installing a second hard drive on a desktop PC running Windows 7. The second hard drive is the same make and model of the first hard drive. The technician would like to provide data redundancy. Which of the following should the technician use to accomplish this?

A. Disk Management
B. Device Manager
C. System Configuration
D. Data Sources

Correct Answer: A

Explanation:
http://support.microsoft.com/kb/309000

CompTIA A+ Core 2 Question H-26

A technician responds to a hardware issue with a server. The technician discovers that one of the hard drives in the server has failed. The server is set up in a RAID 1 configuration. Which of the following steps would the technician perform NEXT?

A. Remove the hard drive and back up the data
B. Run CONVERT on the hard drive
C. Reboot the server
D. Swap hard drive and rebuild array

CompTIA A+ Core 2 Question H-25

A technician needs to build a PC to act as a home virtual server. Which of the following would be the BEST choice?

A. Dual Core CPU, 6GB DDR3 RAM, 320GB of hard drive space
B. Dual Core CPU, 8GB DDR RAM, 1TB of hard drive space
C. QUAD Core CPU, 6GB DDR3 RAM, 320GB of hard drive space
D. QUAD Core CPU, 4GB DDR2 RAM, 1TB of hard drive space

Correct Answer: C

Explanation:
Virtual server hosts a lot of virtual machines that host various operating systems and applications. Therefore, you need maximum cores and memory to keep all the virtual machines humming properly. More cores and more memory means you can have more physical resources to create virtual resources that will be used to host virtual machines.

CompTIA A+ Core 2 Question H-24

A technician discovers that a hard drive has died in a RAID 0 configuration. Which of the following would be the outcome of this situation?

A. The user will need to replace the PC.
B. The technician will need to back up and replace the drive.
C. The user will lose all non-backed up data.
D. The technician will need to replace the drive and rebuild the array

Correct Answer: C

CompTIA A+ Core 2 Question H-5

Jane, a home user, brings a Windows XP PC in for repair and reports that several disk read errors are occurring. She has run check disk and errors have been reported several times. Which of the following should a technician recommend? (Select TWO).

A. Increase the amount of RAM to improve disk checks
B. Backup all data on the drive
C. Upgrade to a home server
D. Purchase a new hard drive
E. Change the drive configuration to RAID 0
F. Upgrade to Windows 7 Professional

Correct Answer: BD

Explanation:
First backup all the data from the drive to prevent data loss. Get a new hard drive and restore the data on the new drive.

CompTIA A+ Core 2 Question G-88

After accidentally removing a hard drive from a server with three drives in a RAID 5 configuration, a technician notices the server locks up and shuts down. Which of the following can the technician do to quickly fix the problem?

A. Replace the RAID controller and boot.
B. Reinsert the drive and boot.
C. Plug the drive back in, the system will resume automatically.
D. Remove all drives and rebuild the array.

Correct Answer: B

Explanation:
Just reinsert the drive and boot the computer. The computer will start since it is a RAID 5 configuration.

CompTIA A+ Core 2 Question G-81

A user recently purchased a new PC with a 500GB hard drive. However, they are reporting that their C Drive is only 420GB. Which of the following BEST explains this?

A. The manufacturer blocks off that 80GB so that user cannot exceed the drive space.
B. The file system is using the 80GB for tables.
C. BIOS and systems files are hidden in the 80GB.
D. A Factory Recovery Partition is using the 80GB.

Correct Answer: D